Searching for the Most Suitable Condition and the Suggestion of Each Application in Ultrasonic Shot Peening

Author:  Hattori, Watanabe, Handa, Duchazeaubeneix
Source:  Conf Proc: ICSP-8 Sept. 16-20, 2002 Garmisch-Partenkirchen, Germany
Doc ID:  2002005
Year of Publication:  2002
Abstract:  
Authors Kaneshi Hattori, Yoshihiro Watanabe, Mitsuru Handa, Tokyo Seiko, Japan, Jean-Michel Duchazeaibeneix Sonats, France Abstract Ultrasonic shot peening, named Stressonic, developed by SONATS, is being popularized among aeronautic industries for production parts and maintenance application because of its compact equipment that allows treatment partially and it can be integrated into production line. However, Stressonic has a big difference in processing method compared to that of classical shot peening. Therefore, the peening management, which influences the peening effect, needs to be renewed. In this report, treatment conditions as amplitude, shot media (material, diameter), injecting distance, are set as Stressonic management items. Then the most suitable Stressonic condition is experimented by intensity and residual stress distribution obtained from the management above. Stressonic application is also studied using parts, such as gears and springs, and confirmed its quality after Stressonic process. As a result of study and experiment, Stressonic application has an outstanding peening effect.


Download PDF