Abstract:
This investigation systematically approached the effect of peening and re-peening upon the fatigue life of partially fatigued notched components made of high stength 7075 AI-Zn alloy, loaded under axial tension-tension conditions. It has bee found that peening partially fatigued specimens not previously shot peen treated can be beneficial as the total fatigue life of failure extends by as much a 115% under certain conditions, as compared to the shot peened life. However, re-peening was found to provide little benefits and in some cases it had a detrimental effect. X-ray diffraction measurements have shown that peening after partial fatigue and re-peening induced residual stresses were not as intense as those induced on 'virgin' material.